Advanced Search

Journal Navigation

Journal Home

Subscriptions

Archive

Contact Us

Table of Contents

Sign In to gain access to subscriptions and/or personal tools.
Journal of Biomaterials Applications
This Article
Right arrow Full Text (PDF)
Right arrow References
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Saved Citations
Right arrow Download to citation manager
Right arrowRequest Permissions
Right arrow Request Reprints
Right arrow Add to My Marked Citations
Citing Articles
Right arrow Citing Articles via Google Scholar
Right arrow Citing Articles via Scopus
Google Scholar
Right arrow Articles by Johansson, E.
Right arrow Articles by Gorton, L.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Johansson, E.
Right arrow Articles by Gorton, L.
Social Bookmarking
 Add to CiteULike   Add to Complore   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati   Add to Twitter  
What's this?

Study of a Reagent- and Mediatorless Biosensor for D-Amino Acids Based on Co-Immobilized D-Amino Acid Oxidase and Peroxidase in Carbon Paste Electrodes

Elisabeth Johansson

Department of Analytical Chemistry University of Lund P.O. Box 124, S-221 00 Lund, Sweden

György Marko-Varga

Department of Analytical Chemistry University of Lund P.O. Box 124, S-221 00 Lund, Sweden

LO Gorton

Department of Analytical Chemistry University of Lund P.O. Box 124, S-221 00 Lund, Sweden

A biosensor for the analysis of D-amino acids is described. Carbon paste (graphite/paraffin oil) was chemically modified with immobilized D-amino acid oxidase and either horse-radish peroxidase or fungal peroxidase from Arthromyces ramosus. The two enzymes dissolved in buffer, together with an amine containing oligomer or polymer, were adsorbed on dry graphite. Prior to immobilization, the graphite was heat treated at 700°C for 15 s to promote an efficient electron transfer between graphite and the peroxidase. The mixture was dried before addition of the pasting liquid. The sensor is based on the fact that the hydrogen peroxide produced by the action of D-amino acid oxidase is electrocatalytically reduced through the action of the peroxidase. The amine containing compound acted as a stabilizer and activator of the enzymes in the paste. The enzyme electrode was investigated as a sensor for D-phenylalanine and hydrogen peroxide in a flow through electrochemical cell connected to a single line flow injection system. The influences on the response by different additives to the paste and pH are reported. Linear calibration curves were obtained between 0.1 and 1.4 mM for D-phenylalanine and 5 and 1000 µM for hydrogen peroxide at an applied potential of -50 mV vs. Ag/AgCl. The sensor was also active for the following D-amino acids: D-alanine, D-valine, D-leucine, D-isoleucine, D-serine, D-aspartic acid, D-glutamic acid, D-lysine, D-histidine, D-arginine, D-tryptophan, D-methionine, and D-proline.

Journal of Biomaterials Applications, Vol. 8, No. 2, 146-173 (1993)
DOI: 10.1177/088532829300800204


Add to CiteULike CiteULike   Add to Complore Complore   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati   Add to Twitter Twitter    What's this?