Advanced Search

Journal Navigation

Journal Home

Subscriptions

Archive

Contact Us

Table of Contents

Sign In to gain access to subscriptions and/or personal tools.
Journal of Biomaterials Applications
This Article
Right arrow Full Text (PDF)
Right arrow References
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Saved Citations
Right arrow Download to citation manager
Right arrowRequest Permissions
Right arrow Request Reprints
Right arrow Add to My Marked Citations
Citing Articles
Right arrow Citing Articles via Google Scholar
Right arrow Citing Articles via Scopus
Google Scholar
Right arrow Articles by Ramesh, P.
Right arrow Articles by Sunny, M. C.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Ramesh, P.
Right arrow Articles by Sunny, M. C.
Social Bookmarking
 Add to CiteULike   Add to Complore   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati   Add to Twitter  
What's this?

A Comparative Evaluation of Coefficient of Friction and Mechanical Properties of Commercially Available Foley Catheters

P. Ramesh

Biomedical Technology Wing, Sree Chitra Tirunal Institute for Medical Sciences & Technology, Poojappura, Thiruvananthapuram—695 012, Indiarameshp{at}sctimst.ker.nic.in;bmtwing@md2.vsnl.net.in

R. Joseph

M. C. Sunny

Biomedical Technology Wing, Sree Chitra Tirunal Institute for Medical Sciences &Technology, Poojappura, Thiruvananthapuram—695 012, India

Three commercially available urinary catheters were evaluated for their coefficient of friction and mechanical properties, which are two important parameters as far as the intended use is considered. The apparent coefficient of friction was measured from the slope of the force versus normal load graph using an in-house fabricated setup. Themechanical properties like ultimate tensile strength, elongation at break and modulus were evaluated before and after aging in synthetic urine. The swelling behavior of the catheter samples was studied in toluene and found to correlate well with the mechanical properties.

Key Words: Foley catheters • coefficient of friction • tensile strength • modulus

Journal of Biomaterials Applications, Vol. 15, No. 4, 344-350 (2001)
DOI: 10.1106/NCRR-MDV5-FQFG-L7PG


Add to CiteULike CiteULike   Add to Complore Complore   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati   Add to Twitter Twitter    What's this?